Staple Channel Rebuild - Model 445FS (back)
3.18
 

Click here for the Video
Use the PLAY, Pause and Stop Controls Above
or click here for the Video and Sound.

Staple Channel Rebuild - Model 445FS Pneumatic Stapler.

Remove the adapter foot and staple channel from the stapler.

Also separate the staple channel from the adapter foot.

Remove the four 3/4" socket head cap screws from the steel foot.
Remove the steel foot.
Remove the two 3/8" socket head cap screws that are holding the gate plate and gate to the channel.
Remove the gate plate.
Check the gate and gate plate for any wear or obstructions.
Remove the 2 hex head screws holding the gate to the channel.
Remove the gate.
Slide the staple pusher out of the channel.
Remove the 1/4" screw from the pusher spring.
Remove the spring.
Though rarely necessary, you can disassemble the channel further by removing the 2 bottom screws.
Slide out the inner channel core.
Staple channel is ready for reassembly.

To assemble the channel, slide the channel core between the two shaft guides.
Reinstall and tighten the channel base screws.
Insert the pusher spring with the 1/4" flat head cap screw.
Reinstall the staple pusher.
While holding the staple pusher back, place the gate at the end of the channel.
Reinstall the (2) 1/2" gate screws to the center of the gate.
Set the gate plate over the gate.
Use the (2) 3/8" socket head cap screws to attach the gate plate to the gate.

Tighten firmly.

Put the steel foot over the gate plate.
Use the (4) 3/4 socket head cap screws to reinstall the steel foot.

Firmly tighten all four screws.

Staple channel rebuild is now complete.